 Reference, Installation, and Operations Manual
Section 5: Startup and meter configuration
3-9000-743 Rev S
June 2013
Connect a Mark III Meter to a LAN via an Ethernet Hub
 109
5.4.3
Connect a Mark III Meter
 
to a LAN via an Ethernet Hub
When connecting a Daniel 3410 Series Gas Ultrasonic Flow Meter to a LAN via an Ethernet hub, 
refer to the wiring diagram (
drawing DE-21056) for on wiring instructions the 
Daniel Mark III Ultrasonic Gas Flow Meter Ethernet connector to one of the Ethernet hub ports.      
Plug one end of the straight-through patch cable (from the LAN) into the hub UPLINK port.
Using Daniel MeterLink on the PC, either modify an existing meter directory record for the 
meter (such as from initial communication set-up) or create a new meter directory record for 
the meter. Modify the record’s Ethernet parameters to the user-configured values.
5.5
Serial port connections using RS-232 serial cable
Serial port configurations 
For serial port communications, configure the data points listed in the table below using Daniel 
MeterLink 
Meter|Communications Settings
 menu path. Note that only Port A offers RTS/CTS 
handshaking. All ports (when in slave mode) provide automatic protocol detection for the 
following protocols:
ASCII Modbus (7 data bits, even or odd parity, 1 stop bit)
RTU Modbus (8 data bits, no parity, 1 stop bit)
TCP/IP
The Ethernet adapter cable (Daniel P/N 3-3400-079) is specifically for connecting the Daniel 
3410 Series Gas Ultrasonic Flow Meter to a PC Ethernet connector. It cannot be used to 
connect the meter to an Ethernet hub.
Do not connect the Series 100 Option Board to the hub UPLINK port. Also, most hubs do not 
allow use of the port immediately next to the hub UPLINK port when the UPLINK port is used 
to connect the hub to a LAN.
Serial Port A is usually reserved for connection to an external flow computer or RTU. Serial 
Port B is usually reserved for connection to a device, such as a personal computer, that can be 
used to perform meter diagnostics, meter configuration, and other tasks not requiring 
dedicated connection. Serial Port C, provided by the Series 100 Plus Option Board, can be 
used for connection to a flow computer/RTU.