HDV Series Direct Vent Gas Fireplace
VeNtING INStAllAtIoN     
W
ARNING
When installing the appliance as a rear vent unit, the 90°, 45° transition elbow 
attached directly to the rear of the unit is Not INCluDeD in the following 
criteria and calculations, and unless specifically mentioned should be ignored 
when calculating venting layouts.
   The  maximum  number  of  90°  elbows  per  side  wall 
installation is three (3). Figure 20
   If a 90° elbow is fitted directly on top of the fireplace 
flange, the maximum horizontal vent run before the ter-
mination or a vertical rise is 36" (914 mm). Figure  21
FP1176
max 90 bends
Figure 20 - 
Maximum Three (3) 90° Elbows 
Per Installation
3 x 90°
Elbows
3 x 90°
Elbows
FP1176
Max 20"
Max 20"
36"
(914 mm) 
Max.
36"
(914 mm) 
Max.
FP1177
max horizontal run
Figure 21 - 
Maximum Horizontal Run with No Rise
FP1177
   If a 90° elbow is used in the horizontal vent run (level 
height maintained) the horizontal vent length is reduced 
by 36" (914 mm) (Fig. 1 A and B) This does not apply if 
the 90° elbows are used to increase or redirect a vertical 
rise. Figure 22
Example: According to the vent graph (page 17) the maxi-
mum horizontal vent length in a system with a 7.5' vertical 
rise is 20’ (6 m) and if a 90° elbow is required in the hori-
zontal vent it must be reduced to 17' (5.2 m). 
In  Figures  22  and  24,
  Dimension A  plus  B  must  not  be 
greater than 17' (5. m).
A: 10’
B: 7’
7’6”
FP1959
max run w/elbows
Figure 22 - 
Maximum Vent Run with Elbows
Horizontal 90° Elbow = 3' Reduction
FP1959
A + B = 17' Maximum
A
B
7’6”
90°
FP2413
horz run reduct
Figure 23 - 
Horizontal Run Reduction 
FP466