Monessen Hearth IDV490NVC 用户手册

下载
页码 40
18 
57D0016
3" M
inim
um
INSERT INSTALLATION 
A listed manual shutoff is factory installed upstream of appliance. Union tee and plugged 
1
/
8
" NPT pressure tapping point 
should be installed upstream of the appliance. See Figure 15.
IMPORTANT: The main gas valve is for turning on or shutting off the gas to the insert. 
Check your building codes for any special requirements for 
locating equipment shutoff valve to inserts.
Apply pipe joint sealant lightly to threads. This will prevent 
excess sealant from going into pipe. Excess sealant in pipe 
could result in clogged burner system valves.
A  manual  shutoff  valve  is  factory 
installed  upstream  of  the  appliance. 
Union  tee  and  plugged 
1
/
8
"  NPT 
pressure  tapping  point  should  be 
installed  upstream  of  the  appliance. 
See Figure 15.
CAUTION
Use pipe joint sealant that is resistant 
to liquid petroleum (LP) gas. 
CAUTION 
We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 15. Locate sediment trap/drip 
leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment 
trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them 
from going into the burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system 
may not run properly. 
Figure 15 - Gas Connection 
Tee Joint
Pipe Nipple
Cap
Approved Flexible 
Gas Line Supplied 
with Appliance 
Sediment Trap/Drip Leg 
Natural Gas
From Gas Meter 
(4.5" W.C. to 10.5" W.C. Pressure)
Propane/LP
From External Regulator 
(11" W.C. to 13" W.C. Pressure)
NOTE :  The gas line connection may be made using 
1
/
2
" rigid tubing or an approved flex connector. Since 
some municipalities have additional local codes it is always best to consult your local authorities 
and the current edition of the National Fuel Gas Code ANSI.Z223.1, NFPA54. In Canada CAN/CGA-
B149 (1 or 2) Installation Code. 
Only  persons  licensed  to  work  with 
gas  piping  may  make  the  necessary 
gas connections to this appliance. 
W