FIREPLACE INSTALLATION 
A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 
1
/
8
" NPT pressure tapping 
point should be installed upstream of the appliance. See Figure 24.
IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is 
for turning on or shutting off the gas to the fi replace. 
Check your building codes for any special requirements for 
locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male threads. This will 
prevent excess sealant from going into pipe. Excess sealant in 
pipe could result in clogged burner system valves.
A manual shutoff valve must be installed 
upstream of the appliance. Union tee 
and plugged 
1
/
8
" NPT pressure tapping 
point should be installed upstream of 
the appliance. See Figure 24.
CAUTION
Use pipe joint sealant that is resistant 
to liquid petroleum (LP) gas. 
CAUTION 
We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 24. Locate sediment trap/drip 
leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment 
trap/drip leg where trapped matter is not likely to freeze. A sediment trap collects moisture and contaminants and keeps 
them from going into the burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner 
system may not run properly. 
Figure 24 - Gas Connection 
Tee Joint
Pipe Nipple
Cap
Approved Flexible 
Gas Line 
CSA Design-Certifi ed Equipment 
Shutoff Valve with 
1
/
8
" NPT Tap*
Sediment Trap/Drip Leg 
Natural Gas
From Gas Meter 
(4.5" W.C. to 10.5" W.C. Pressure)
Propane/LP
From External Regulator 
(11" W.C. to 13" W.C. Pressure)
NOTE : The gas line connection may be made using 
1
/
2
" rigid tubing or an approved fl ex connector. Since 
some municipalities have additional local codes it is always best to consult your local authorities and 
the current edition of the National Fuel Gas Code ANSI.Z223.1, NFPA54. In Canada CAN/CGA-B149 (1 or 
2) Installation Code. 
Only persons licensed to work with 
gas piping may make the necessary 
gas connections to this appliance. 
W