 P36-4 Gas Log Fireplace
5
INSTALLATION 
CHECKLIST
1)  Locate appliance
 a) 
Locate 
Your 
Gas 
Fireplace
 b) 
Clearances
 c) 
Combustible 
Mantels
 d) 
Framing 
Finishing
2)  Assemble Top Standoffs and Top Facing 
Support and Side Nailing Strips, refer to 
section "Unit Assembly Prior to Installation". 
(NOTE: must be done before installing unit 
into fi replace.)
3)  Install fl ue (Refer to section "Simpson Dura-
vent Flueing").
4)  Make gas and electrical connections. Test 
the pilot. Must be as per diagram. Refer to 
section "Pilot Adjustment."
5)  Install standard and optional features.  Refer 
to the following sections:
 
 a. 
Brick 
Panels
 
b. Log Set
 c. 
Flush 
Door
 d. 
Premium 
Flush 
Front
 e. 
Bay 
Door
 f. 
 
Hampton
®
 Cast Faceplate
 g. 
Hampton
®
 Cast Grills
 h. 
Wall 
Switch
 
i.  Remote Control
 j. 
 
Wall 
Thermostat
 k. 
Fan
6) Final 
check.
Before leaving this unit with the customer, 
the installer must ensure that the appliance is 
fi ring correctly and operation fully explained 
to customer
.
This includes:
1)  Clocking the appliance to ensure the correct 
fi ring rate (rate noted on label 30,000 Btu/h) 
after burning appliance for 15 minutes.
2)  If required, adjusting the primary air to ensure 
that the fl ame does not carbon. First allow 
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that 
causes sooting or carboning that results 
in damage is not the responsibility of the 
manufacturer.
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE INSTRUCTIONS
The P36-NG or P36-LPG Room Sealed Fireplace 
must be installed in accordance with AS5601-
2004 and NZS 5261 5261 and these instructions. 
Carefully read all the instructions in this manual 
fi rst. Consult the "authority having jurisdiction" 
to determine the need for a permit prior to 
starting the installation. It is the responsibility of 
the installer to ensure this fi replace is installed 
in compliance with manufacturer's instructions 
and all applicable codes.
BEFORE YOU START
NOTE: NOT INTENDED AS A FIREPLACE 
INSERT.
GENERAL SAFETY 
INFORMATION
1)  The appliance shall be installed in 
accordance with the manufacturer's 
installation instructions,local gas fi tting 
regulations, municipal building codes, 
water supply regulations, electrical wiring 
regulations, with AS5601-2004 (AGA 
gas installation code) NZS 5261 (New 
Zealand)
2)  Installation and repair should be done 
ONLY by an authorised person.  
3)  THIS APPLIANCE IS NOT INTENDED AS A 
FIREPLACE INSERT. DO NOT CONNECT 
TO MASONARY FLUE.
4)  This appliance must be connected to 
the specifi ed  fl ue  and  termination  cap 
to the outside of the building envelope. 
Never fl ue to another room or inside a 
building. Make sure that the fl ue is fi tted 
as per Flueing instructions.
5)  Inspect the fl ueing system annually for 
blockage and any signs of deterioration.   
6)  Flueing terminals shall not be recessed into 
a wall or siding.
7)  Any safety glass removed for servicing 
must be replaced prior to operating the 
appliance.
8)  To prevent injury, do not allow anyone who 
is unfamiliar with the operation to use the 
fi replace.
9)  Wear gloves and safety glasses for protection 
while doing required maintenance.
10) Be aware of electrical wiring locations in 
walls and ceilings when cutting holes for 
termination.
11) Under no circumstances should this 
appliance be modifi ed. Parts that have to be 
removed for servicing should be replaced 
prior to operating this appliance.
12)  Installation and any repairs to this appliance 
should be done by an authorised service 
person. An authorised service person should 
be called to inspect this appliance annually. 
Make it a practice to have all of your gas 
appliances checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid 
fuels (wood, paper, cardboard, coal, etc.) 
be used in this appliance.
15) The appliance area must be kept clear and 
free of combustible materials, (gases and 
other fl ammable vapours and liquids).
INSTALLATION AND REPAIR SHOULD 
BE DONE BY A AUTHORISED SERVICE 
PERSON. THE APPLIANCE SHOULD BE 
INSPECTED BEFORE USE AND AT LEAST 
ANNUALLY BY AN AUTHORISED SERVICE 
PERSON. MORE FREQUENT CLEANING 
MAY BE REQUIRED DUE TO EXCESSIVE 
LINT FROM CARPETING, BEDDING 
MATERIAL, ETC. IT IS IMPERATIVE THAT 
CONTROL COMPARTMENTS, BURNERS 
AND CIRCULATING AIR PASSAGEWAYS 
OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE 
APPLIANCE SHOULD BE LOCATED OUT 
OF TRAFFIC AND AWAY FROM FURNITURE 
AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS 
APPLIANCE CORRECTLY WILL VOID YOUR 
WARRANTY AND MAY CAUSE A SERIOUS 
HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE 
ALERTED TO THE HAZARDS OF HIGH 
SURFACE TEMPERATURES, ESPECIALLY 
THE FIREPLACE GLASS, AND SHOULD 
STAY AWAY  TO AVOID  BURNS  OR 
CLOTHING IGNITION.  
Y O U N G   C H I L D R E N   S H O U L D   B E 
CAREFULLY  SUPERVISED WHEN THEY 
ARE IN THE SAME ROOM AS THE 
APPLIANCE.
CLOTHING OR OTHER FLAMMABLE 
MATERIAL SHOULD NOT BE PLACED ON 
OR NEAR THE APPLIANCE. DO NOT USE 
AEROSOLS IN THE VICINITY OF THIS 
APPLIANCE.