Quadra-Fire · Castile Gas Stove · 7023-111E
D. 
How to Use the Vent Graph
E. 
Venting Guidelines
1.  Measure the vertical distance from the top of appliance 
to the center of the 90° elbow. On the graph below, draw 
a horizontal line from that measurement on the vertical 
axis across until it intersects with the slanted  line.
2.  From the point of this intersection, draw a vertical line to 
the bottom of the graph.
3.  The point at which this line meets the bottom line of the 
graph is the maximum length of the horizontal run. 
EXAMPLE 1: If the vertical dimension from the center line of 
the flue vent to the center of the 90° elbow is 7 ft. (2.13 m), 
the horizontal run to the outer wall flange must not exceed 
16 ft. (5m).
EXAMPLE 2: If the vertical dimension from the center line of 
the flue vent is 21 ft. (6m), the horizontal run to the outer wall 
flange must not exceed 12 ft. 10 in. (4m).
4.  Each 90° elbow is equivalent to 3 ft. (914mm) of vent 
pipe and each 45° elbow is equivalent to 1 ft. (305mm) 
of vent pipe, and must be subtracted from vent pipe 
run. A single vertical to horizontal 90° elbow is already 
calculated into the allowable 20 ft. (6m) run. Each 
additional 90° elbow reduces the maximum horizontal 
distance by 3 ft. (914mm).
EXAMPLE: The use of 3 elbows would reduce the allowable 
horizontal run to 9 ft. (3 -1 =  2 elbows x 3 ft. = 6 ft.; 20 ft. max. 
- 6 ft. = 14 ft. max.).
NOTE: IF YOUR INSTALLATION FALLS 
WITHIN A SHADED AREA ON THE 
GRAPH, THE DAMPER MUST BE USED. 
SEE INFORMATION ON DAMPER 
ADJUSTMENT ON PAGE 34.
NOTES
 
  The maximum horizontal vent run is 20 ft (6m) when 
the vertical vent rise is 10 ft. (3m).
 
 
The minimum horizontal vent run is 6 in. (152mm).
 
 
Horizontal sections require a 1/4 in. (6mm) rise for 
every 12 in. (305 mm) of horizontal travel.
 
  Exterior Vent Diameter = 6-5/8 in. (168mm); Inner 
Vent Diameter = 4 in. (102mm).
 
  Horizontal sections require noncombustible support 
every 3 ft. (914mm), e.g. wall straps.
 
For any vertical termination a minimum of 6 ft. (2m)  
vertical must be used.
 
Minimum vertical from appliance top before adding 
an elbow is 2 in. (51mm).
EXCEPTIONS FOR HORIZONTAL INSTALLATIONS:
*When installing this appliance in a rear vent configuration 
with no vertical rise, a Snorkel Kit must be used.
*The maximum horizontal vent run is 3 ft. (914mm)
*The maximum horizontal vent run with a 45° elbow is 2 
ft.  (609mm).
*The minimum horizontal vent run is 6 in. (152mm).
NOTE: In the Commonwealth of 
Massachusetts, the word damper 
shall be replaced with the words flue 
restrictor.
40 ft. Maximum Vertical 
HHW2
Example 1
Example 2
No Damper  
in this area
Damper position 
more  OPEN in this 
area
2'           4'          6 '          8'          10'         12'        14'   15'  16'  17'  18'  19'  20'
2'
4'
6'
8'
10'
12
'
14'
16'
18'
20'
22'
24'
26'
28'
30'
32'
34'
35'
36'
37'
38'
39'
40'
Part #SLK-991DA
3 ft. (91 cm) Maximum Horizontal run with no 
vertical pipe and with 1/4 in. (6.35 mm) rise per 
foot. Must use Snorkel cap.
Damper position 
more CLOSED in 
this area
6 ft. Min. Vertical 
Termination
For rear vent or top of 
stove for top vent.
C
L
6 in. Min. starter pipe
C
L
VERTICAL DISTANCE FROM 
APPLIANCE TO 90° ELBOW
Figure 5.2