E.  PRE-INSTALLATION PREPARATION
Installation and repair should be done by a qualified service technician. The appliance should be inspected before
use and at least annually by a qualified service technician. More frequent cleaning may be required due to excessive
lint  from  carpeting,  bedding  material,  etc.  It  is  imperative  that  control  compartments,  burners  and  circulating  air
passageways of the appliance be kept clean.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
WARNING!
This appliance may use the B-vent chimney system only and must not be connected to a chimney flue servicing
a separate solid fuel buring appliance.
This appliance must be installed on a noncombustible, flat, solid, continuous surface (i.e. fireplace hearth.)
1. GAS  PRESSURE
For  natural  gas,  the  minimum  inlet  gas  supply
pressure  is  4.5  inches  water  column  (w.c.),  and  the
maximum  inlet  gas  supply  pressure  is  7.0  inches
w.c. Input rate is 17,000 to 22,000 Btu/hr. For propane
gas,  the  minimum  inlet  gas  supply  pressure  is  11.0
inches  w.c.  and  a  maximum  14.0  inches  w.c.  Input
rate is 15,000 to 22,000 Btu/hr.
Manifold pressure for this appliance is 1.7 - 3.5 inches
w.c.  for  natural  gas  and  5.4  -  11.0  inches  w.c.  for
propane  gas.  This  appliance  has  a  variable  adjust
manifold.
Input  (line)  and  output  (manifold)  pressure  taps  are
located at the front of the gas control valve near the
variable  regulator  for  test  gauge  connection  with  a
3/8”  diameter  hose.
A  1/8”  NPT  plugged  tapping  is  provided  on  the  gas
control  valve,  near  the  outlet  to  the  main  burner
immediately  upstream  of  the  gas  supply  connection
to  the  appliance,  accessible  for  a  test  gauge
connection.
2. HIGH ALTITUDE INSTALLATION
U.S. Installation: Appliances are tested and approved
for elevations from 0-2000 feet (0-610m).
When installing this appliance at an elevation above
2000 feet, it may be necessary to decrease the input
rating  by  changing  the  existing  burner  orifice  to  a
smaller  size.  Input  should  be  reduced  4%  for  each
1000 feet above sea level. Check with the local gas
utility for proper orifice size identification and to see if
the  gas  in  your  area  has  been  deregulated.  This
appliance is shipped with a .093 in./2.36 mm. orifice
size on natural gas versions and a .056 in./1.42 mm.
orifice size on propane gas versions.
Canadian  Installation:  Appliances  are  certified  for
elevations  from  0-4500  feet.  When  installing  this
appliance  at  an  elevation  between  0-4500  feet  in
Canada, the input rating does not need to be reduced.
When installing this appliance at an elevation above
4500 feet in Canada, check with local authorities.
Consult  your  local  gas  company  for  assistance  in
determining the proper orifice for your location or refer
to ANSI Z23.1-latest edition, Appendix F.
3. COMPONENTS
Before installing this appliance, it may be necessary
to  remove  the  smoke  shield,  ash  lip,  refractory,
damper  blade,  etc.  If  removed,  the  label  referenced
on page 7 MUST be affixed to the existing fireplace
prior  to  installation.
WARNING!
To prevent contact with sagging or loose insulation, the appliance must not be installed against vapor barriers
or exposed insulation.