5100-I  ACT WOOD INSERT
438-0380D
September 1, 2008
F. Masonry Fireplace
UL 1777 Insulated Stainless Steel 
Liner or Other Approved Lining System 
Follow Manufacturer’s Instructions 
on Insulation and Support 
For Zero or Other Non-Code Clearances, 
Follow Approved Liner Manufacturer’s Specific 
Insulation Requirements:  Different Clearances 
May Require Different Specifications 
Masonry Chimney Must 
Have Structural Integrity 
UL 1777 Insulated Stainless Steel 
Liner or Other Approved Lining System 
Minimum 8 in. (203mm) Masonry 
Thickness in Front of Smoke Chamber
Damper Plate Removed or 
Fastened in Open Position 
Seal with Non-Combustible Material 
Minimum Clearance in Accordance 
with Insert Listing 
Floor Protection in 
Accordance with Insert 
Listing 
Follow Manufacturer’s 
Instructions for Maximum 
Liner Extension Above 
Chimney 
Maximum 30
 
Degrees 
Offset in Chimney 
Combustible Floor 
The Quadra-Fire 5100-I Insert conforms with the UL 18 
and ULC S68 (Canada) in all respects, and is approved to 
UL & ULC safety standards for installation and use within a 
fireplace with a masonry chimney in accordance with NFPA 
211.
In the USA all masonry fireplace installations require a stain-
less steel liner connector pipe extending to the first flue liner 
of the existing code approved masonry chimney. In Canada,
a full reline is required.
NOTE:    In  Canada,  the  chimney  liner  must  conform  to
the  Class    requirements  of  CAN/ULC-S65,  Standard 
for Lining Systems for Existing Masonry or Factory-Built 
Chimneys  and  Vents,  or  CAN/ULC-S60,  Standard  for 
Lining Systems for New Masonry Chimneys.
NOTE:
  Installation into fireplaces without a permit will 
void the listing.
Figure 17.1