4100-I  ACT WOOD INSERT
Page 12
   September 1, 2008
R
250-7201E
Leveling Bolts
Sheet Metal Shims
Place under leveling bolts 
and slide insert into place
Leveling Bolt
Reach between side of insert and outer skin
cut-out view
This product shipped with two leveling bolts, and two sheet 
metal guides for ease in sliding the insert into place when 
using the leveling bolts.  Not all installations will require the 
use of the leveling bolts.  The sheet metal guides are used 
only when the leveling bolts are necessary.   Discard if not 
needed.
ADJUSTiNg THE lEVEliNg BOlTS
It is best to use a 1/2 inch (12.7mm) socket wrench with an 
extended handle for ease in adjusting bolts to the desired 
level.  The bolts will adjust from 0 to 2 inches (0 - 51mm).  
You can also reach in and adjust the bolts by hand, although 
space is limited.  
Figure 12A.
 LEVELING BOLTS AND SHEET METAL SHIMS
SHEET METAL GUIDES
Slide  each  guide  under  the  insert  on  each  side  placing 
them directly under leveling bolts.  If they are not directly 
under the bolts, the bolts may hang up on uneven material 
when sliding the insert into place.  
See Figure 12B.
Figure 12A
Figure 12B
INSTALLATION IN CANADA
 
  
MASONRY and HEAT-CIRCULATING
(INSTALLATIONS INTO FACTORY-BUILT FIREPLACES ARE PROHIBITED IN CANADA)
Whether installed in a masonry or heat-circulating fireplace, this fireplace insert must be installed with a continuous chim-
ney liner of six inch (152mm) diameter extending from the fireplace insert to the top of the chimney. The chimney liner must 
conform to the Class  requirements of CAN/ULC-S65, Standard for Lining Systems for Existing Masonry 
or Factory-Built 
Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.
 
• Do not remove bricks or mortar from fireplace to accommodate insert.  
• The face of the fireplace must be sealed to prevent room air passage into the chimney cavity.
• The permanent metal warning label provided must be affixed to the back of the fireplace with screws or nails to 
the fireplace, in a location readily visible should the fireplace insert by removed, stating that the fireplace may 
have been altered to accommodate the insert, and must be returned to original condition for use as a conven-
tional fireplace.
• Circulating air chambers may not be blocked.