Enviro Meridian 用户手册

下载
页码 44
Rain cap
Storm collar
Seal plate
(cover plate)
Existing masonry
flue
Vent pipe (single
wall stainless flex
pipe or solid PL
vent)
Fireplace damper
location
Clean out tee
Existing fireplace
Flexible vent
connector (use this
5' [1520 mm] section
of pipe to vent past
fireplace damper or
small shelf)
1. Lock  fireplace  damper  in  the  open 
position.
2. Install  a  positive  flue  connector  at  the 
fireplace dampers.
3. Connect a clean-out tee or a 90° elbow to 
the exhaust pipe.
4. Install flexible stainless steel liner or listed 
pellet vent to the top of the chimney.
Floor
Protection
Combustible Floor
Masonry Fireplace
Min 6"
(150 mm)
Mantel
Minimum 8" (20 cm)
from top of stove
Damper Removed
or Fastened Open
Clean-out
Fresh-air intake
should com from
chimney. If holes
already exist fresh-air
intake can be taken
through back of the
fireplace or through
the ash dump.
Installation
H
EARTH
 M
OUNT
 I
NSTALLATION
 - F
REESTANDING
:
Figure 29: Hearth Mount - Side View. 
Figure 30: Hearth Mount - Over View. 
23