Quadra-Fire  •  Topaz  •  7009-113  Rev. J  •  12/11
4
Termination Locations
A. Vent Termination Minimum Clearances
Figure 4.2   Multiple Vertical Termination
Figure 4.1  Termination Clearances
Figure 4.3 specifi es minimum vent heights for various 
pitched roofs.
 
Figure 4.3   Minimum Height from Roof to Lowest Discharge
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles 
as specifi ed.
WARNING
•  Do not pack air space with insulation or 
other materials.
Failure to keep insulation or other materials 
away from vent pipe may cause fi re.
HORIZONTAL
OVERHANG
VERTICAL
WALL
GAS DIRECT VENT 
TERMINATION CAP
12
X
ROOF PITCH
IS  X/ 12
LOWEST 
DISCHARGE 
OPENING
2 FT.
MIN.
20 INCHES MIN.
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
Roof Pitch
H (Min.) Ft.
Flat to 6/12 ......................................................... 1.0*
Over 6/12 to 7/12
........................................................ 1.25*
Over 7/12 to 8/12 ............................................... 1.5*
Over 8/12 to 9/12 ............................................... 2.0*
Over 9/12 to 10/12 ............................................. 2.5*
Over 10/12 to 11/12 ........................................... 3.25
Over 11/12 to 12/12 ........................................... 4.0
Over 12/12 to 14/12 ........................................... 5.0
Over 14/12 to 16/12 ........................................... 6.0
Over 16/12 to 18/12 ........................................... 7.0
Over 18/12 to 20/12 ........................................... 7.5
Measure vertical clearances from this surface.
Measure horizontal clearances from this surface.
(See 
Figure 4.4 for specifi c clearances.)
Opening
Gas, Wood or Fuel Oil
Termination Cap
B
Gas
Termination
Cap **
A *
*
If using decorative cap cover(s), this distance may need to be 
increased. Refer to the installation instructions supplied with the 
decorative cap cover.
**
A
B
6 in. (minimum) up to 20 in.
152 mm/508 mm
18 in. minimum
457 mm
20 in. and over
0 in. minimum
In a staggered installation with both gas and wood or fuel oil 
terminations, the wood or fuel oil termination cap must be 
higher than the gas termination cap.