York R-410A ZH/ZJ/ZR Series 用户手册

下载
页码 206
528150-YTG-G-1210
Johnson Controls Unitary Products
117
ZR078-150 Side Duct Application
ZR078 (6.5 Ton) Side Duct
Air Flow
(CFM)
Available External Static Pressure - IWG
1
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW =  BHP x 0.932.
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
1.5 HP & Field Supplied Drive
Standard 1.5 HP & Drive 
Hi Static 2 HP & Drive
1800
778
0.37
838
0.56
895
0.73
951
0.88
1005
1.01
1059
1.13
1112
1.25
1166
1.36
1221
1.47
1278
1.59
2000
803
0.50
864
0.69
921
0.85
977
1.00
1031
1.14
1085
1.26
1138
1.37
1192
1.49
1247
1.60
1304
1.72
2200
833
0.64
893
0.83
951
1.00
1006
1.14
1061
1.28
1114
1.40
1168
1.51
1221
1.63
1276
1.74
1333
1.86
2400
866
0.80
926
0.99
984
1.15
1039
1.30
1094
1.43
1147
1.56
1201
1.67
1254
1.78
1309
1.90
1366
2.02
2600
902
0.97
962
1.16
1020
1.33
1076
1.47
1130
1.61
1183
1.73
1237
1.85
1291
1.96
1346
2.07
1402
2.19
2800
941
1.16
1002
1.35
1059
1.52
1115
1.67
1169
1.80
1222
1.92
1276
2.04
1330
2.15
1385
2.26
-
-
3000
983
1.37
1043
1.56
1101
1.73
1157
1.88
1211
2.01
1264
2.13
1318
2.25
-
-
-
-
-
-
3200
1028
1.60
1088
1.79
1145
1.95
1201
2.10
1255
2.24
-
-
-
-
-
-
-
-
-
-
3400
1074
1.84
1134
2.03
1192
2.20
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2 HP & Field Supplied Drive
ZR090 (7.5 Ton) Side Duct
Air Flow
(CFM)
Available External Static Pressure - IWG
1
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW =  BHP x 0.932.
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
1.5 HP & Field Supplied Drive
Standard 1.5 HP & Drive 
Hi Static 3 HP & Drive
2000
803
0.50
864
0.69
921
0.85
977
1.00
1031
1.14
1085
1.26
1138
1.37
1192
1.49
1247
1.60
1304
1.72
2200
833
0.64
893
0.83
951
1.00
1006
1.14
1061
1.28
1114
1.40
1168
1.51
1221
1.63
1276
1.74
1333
1.86
2400
866
0.80
926
0.99
984
1.15
1039
1.30
1094
1.43
1147
1.56
1201
1.67
1254
1.78
1309
1.90
1366
2.02
2600
902
0.97
962
1.16
1020
1.33
1076
1.47
1130
1.61
1183
1.73
1237
1.85
1291
1.96
1346
2.07
1402
2.19
2800
941
1.16
1002
1.35
1059
1.52
1115
1.67
1169
1.80
1222
1.92
1276
2.04
1330
2.15
1385
2.26
1442
2.38
3000
983
1.37
1043
1.56
1101
1.73
1157
1.88
1211
2.01
1264
2.13
1318
2.25
1372
2.36
1427
2.47
1483
2.59
3200
1028
1.60
1088
1.79
1145
1.95
1201
2.10
1255
2.24
1309
2.36
1362
2.47
1416
2.59
1471
2.70
1528
2.82
3400
1074
1.84
1134
2.03
1192
2.20
1248
2.35
1302
2.48
1355
2.60
1409
2.72
1463
2.83
1518
2.94
1574
3.06
3600
1123
2.10
1183
2.29
1241
2.46
1297
2.61
1351
2.74
1404
2.86
1458
2.98
1512
3.09
1567
3.21
1623
3.32
3800
1174
2.38
1234
2.57
1292
2.74
1348
2.88
1402
3.02
1455
3.14
1509
3.26
1562
3.37
-
-
-
-
3 HP & Field Supplied Drive
ZR102 (8.5 Ton) Side Duct
Air Flow
(CFM)
Available External Static Pressure - IWG
1
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW =  BHP x 0.932.
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
2 HP & Field
Supplied Drive
Standard 2 HP & Drive 
Hi Static 3 HP & Drive
2200
684
0.48
735
0.67
783
0.84
829
1.01
874
1.17
918
1.32
960
1.48
1001
1.63
1041
1.78
1081
1.94
2400
695
0.58
745
0.76
793
0.94
840
1.11
885
1.27
928
1.42
970
1.57
1011
1.73
1052
1.88
1091
2.04
2600
706
0.67
756
0.86
805
1.04
851
1.20
896
1.36
939
1.52
981
1.67
1023
1.82
1063
1.98
1103
2.13
2800
719
0.78
769
0.96
817
1.14
863
1.31
908
1.47
952
1.62
994
1.78
1035
1.93
1075
2.08
1115
2.24
3000
732
0.89
782
1.08
831
1.25
877
1.42
922
1.58
965
1.74
1007
1.89
1049
2.04
1089
2.19
1128
2.35
3200
747
1.02
797
1.21
846
1.38
892
1.55
937
1.71
980
1.86
1023
2.02
1064
2.17
1104
2.32
1144
2.48
3400
764
1.16
814
1.35
862
1.53
909
1.69
954
1.85
997
2.01
1039
2.16
1080
2.31
1121
2.47
1160
2.62
3600
783
1.33
833
1.51
881
1.69
927
1.86
972
2.02
1016
2.17
1058
2.32
1099
2.48
1139
2.63
1179
2.79
3800
803
1.51
853
1.69
901
1.87
948
2.04
992
2.20
1036
2.35
1078
2.50
1119
2.66
1159
2.81
1199
2.97
4000
825
1.71
875
1.89
923
2.07
970
2.23
1014
2.39
1058
2.55
1100
2.70
1141
2.86
1181
3.01
1221
3.16
4200
849
1.92
899
2.11
947
2.29
993
2.45
1038
2.61
1082
2.77
1124
2.92
1165
3.07
1205
3.23
1245
3.38
3 HP & Field Supplied Drive