Runco RS-900 Series RS1100 Series 用户指南

下载
页码 104
RS-900 and RS1100 Series Installation/Operation Manual
37 
PRE
L
IMINAR
Y
Connecting to AC Power
Projector: The RS-900/RS1100 
ships with various types of AC 
power cords. Choose the one that 
is appropriate to your locale. 
Plug the female end of the power 
cord into the AC receptacle on the 
rear of the projector (AC 100V ~ 
240V). Then, connect the other end 
to your AC power source.
AutoScope Lens Motor: With AutoScope-equipped projectors, an additional power 
cord is provided for the lens motor. Plug the female end of the AC power cord into the AC 
input on the rear of the lens motor assembly. Connect the other end to a 110 VAC power 
source. 
3.7 
Turning on the Power
1.
Turn on your source components. 
2.
If this is an AutoScope-equipped projector, turn on the main power switch at the rear 
of the AutoScope lens motor. The lens motor power switch is located next to the AC 
input (see above). 
3.
Turn on the main power switch at the rear of the projector. The POWER LED lights 
orange. The LAMP and TEMP LEDs light red briefly, then go out. 
4.
Press the ON button on the remote control to turn on the RS-900/RS1100. The 
POWER LED flashes green to indicate that it is warming up. 
5.
When the projector is ready for use, the POWER LED lights solid green. 
6.
“[Input Name] Source Searching” appears on the screen before the RS-900/RS1100 
identifies the input signal and remains there until a valid signal is detected. 
The input voltage to the AutoScope lens motor must be between 
100 and 120 VAC. Do not connect the AutoScope lens motor 
to a 200-240 VAC power source!
Power
switch 
Caution
AutoScope Lens Motor (Rear)
AC Input
Power
Switch
to 
110 VAC
Power