Runco RS-900 Series RS1100 Series 用户指南

下载
页码 104
RS-900 and RS1100 Series Installation/Operation Manual
73 
PRE
L
IMINAR
Y
6.1 
RS-232 Connection 
and Port Configuration
To interface the RS-900/RS1100 with a home theater automation/control system or a PC 
running terminal emulation software:
1. Connect it to your control system or PC as shown in Figure 3-17.
2. Start a terminal session on your PC using a terminal-emulation program, such as 
HyperTerminal. 
3. Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 
stop bit and no flow control. Set the baud rate to 19200. 
4. Type a command from among those listed in Table 6-1. For example, to select the 
Component 1 input, type X133X. Do not send a carriage return after the 
command.
6.2 
Serial Command 
Syntax
Serial commands to the RS-900/RS1100 take the following form:
• Commands are in ASCII format.
• Commands must be in UPPERCASE; for example, X001X, not x001x.
• When you send a valid command, the RS-900/RS1100 performs the following actions:
1. Echoes the command back to the PC or control system, unless the command is 
X001X
 (Power On).
2. Executes the command.
3. Sends a confirmation message in the form X0_[command number]X<CR>. The 
confirmation message does not include the leading zeros in the command. 
For example, when you send the command X003X, the RS-900/RS1100 responds 
with X003XX0_3X<CR>. When you send the command X061X, the RS-900/RS1100 
responds with X061XX0_61X<CR>. When you send the command X133X, the 
RS-900/RS1100 responds with X133XX0_133X<CR>. 
• When you enter an invalid command, the RS-900/RS1100 echoes the command and 
does nothing else.
 
6. Serial Communications
The RS-900/RS1100 will not accept serial commands for 20 
seconds after it is turned on or off. 
Table 6-1. Serial Commands 
Code
Function
X001X
Power On 
X002X
Power Off
X003X
Menu
X004X
Enter
X005X
Exit
Note