Micro Motion
®
 Model 2400S Transmitters 
I/O Wiring – Model 2400S PROFIBUS-DP and DeviceNet Transmitters
4.4
I/O wiring for Model 2400S DeviceNet transmitters
Connect the transmitter to the DeviceNet segment according to the diagram in Figure 4-3. The 
transmitter is shipped with a DeviceNet male sealed Micro Connector (Eurofast) that has been 
preinstalled and wired according to the DeviceNet specification.
Follow all local safety regulations.
Figure 4-3
Model 2400S DeviceNet I/O wiring
WARNING
A transmitter that has been improperly wired or installed in a hazardous area 
could cause an explosion.
To avoid the risk of an explosion:
Make sure the transmitter is wired to meet or exceed local code requirements.
Install the transmitter in an environment that complies with the classification tag 
on the transmitter. See Appendix A.
Attach a 5-pin female 
Eurofast connector here