Drawing Number:
Drawing Date:
H-6-E
September 07, 2008
NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro-
fessional engineering drawing. It is intended only as a guide and does not imply compliance with local 
building code requirements. Confer with local building officials before installation
. The Contractor or 
engineer is to determine the necessary components and configuration of the particular system to be in-
stalled. It is the responsibility of the engineer or contractor to ensure that the installation is in accordance 
with all local building codes.
23
Domestic Hot Water - Optional Freeze Protection
6 Outdoor On-Demand Water Heater
Preferred Piping Installation
On-Demand
Equipment List 
QTY
On-Demand Outdoor       6
Water Heaters
Electronic Connection *
* Refer to On-Demand Accessories 
  and Model Applicability for
  electronic connection details.
IMPORTANT!
With electrical power supplied to a on-demand water heater, it will not freeze in enviornments as cold as -30
  
 F, 
when protected from direct wind exposure.
In the event of a power failure at temperatures below freezing, the water heater should be drained of all water to 
prevent freezing damage.
The unit may be drained manually or through the installation of the Optional solenoid valves as shown.
The electrical connections for the two solenoid valves should be tied to the 120V power terminals provided on the 
PC Board of the water heater.
When the electrical power to the water heater fails, the cold water supply solenoid valve closes, stopping the flow of 
water into the heater, and the drain down solenoid valve opens, allowing the water heater and associated piping to 
drain. Ensure that you run the drain for the solenoids per local codes.
o
Vacuum
Breaker
NOTE:
outside building structure.   These are indicated 
by being above the dashed line.
line should be located inside the building 
structure. 
The vacuum breaker line should be located inside 
the building structure.
Cold Water Supply Line 
Gas Supply Line 
Route drain
per local codes
Hot Water Supply
S
Sub 2
Sub 1
Pri mary
Sub 2
Sub 1
Pri mary
S
Pressure Regulator 
Set to 5 PSI Below 
Street Pressure
Outdoor
On-Demand
Water Heater
Outdoor
On-Demand
Water Heater
Outdoor
On-Demand
Water Heater
Outdoor
On-Demand
Water Heater
Outdoor
On-Demand
Water Heater
Outdoor
On-Demand
Water Heater
Normally Closed Solenoid Valve
(Full Size of Cold Water Supply Line)
1/4 “ Minimum
Normally Open 
Solenoid Valve
NOTE:
Pipes and fittings can be 
installed inside a pipe en-
closure or recess box and
packed with insulation for 
additional protection.
Key
Pressure Relief  Valve
Check Valve
3/4" Union
3/4" Ball  Valve
Boiler Drain Valve
Solenoid Valve
S
Pressure Regulator
Circulating Pump
Mixing Valve