Drawing Number:
Drawing Date:
H-2-RO
September 07, 2008
NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro-
fessional engineering drawing. It is intended only as a guide and does not imply compliance with local 
building code requirements. Confer with local building officials before installation
. The Contractor or 
engineer is to determine the necessary components and configuration of the particular system to be in-
stalled. It is the responsibility of the engineer or contractor to ensure that the installation is in accordance 
with all local building codes.
27
On-Demand
Equipment List 
QTY
On-Demand 
        2
Water Heaters
Domestic Hot Water - Circulation Systems
2 On-Demand Water Heater
Optional Piping Installation
Electronic Connection *
* Refer to On-Demand Accessories 
  and Model Applicability for 
  electronic connection details.
Gas Supply Line
On-Demand
Water Heater
Primary
On-Demand
Water Heater
Sub 1
(Optional)
2-10 Gallon
Storage Tank
(To eliminate cold water
sandwich e ect caused by
fre quent On/O
operation)
Expansion Tank
Minimum 3/4 “ Cold 
Water Supply Line
Minimum 3/4 “ Hot 
Water Supply Line
Building Outlets
For this application:
Pump should be controlled by an Aquastat, 
Timer or Combination Aquastat and Timer.
Pump to be sized to maintain circulation 
loop temperature.
A minimum of 3 GPM flow is recommended 
for the circulation system.
The pump should be sized to overcome the 
pressure loss through the on demand water 
heater, optional storage tank, and supply 
and return plumbing in the circulation loop.
Reference the section Pump Sizing for 
Circulation
.
Pump to be of bronze or stainless construc-
tion.
Aquastat Connection
Key
Pressure Relief  Valve
Check Valve
3/4" Union
3/4" Ball  Valve
Boiler Drain Valve
Solenoid Valve
S
Pressure Regulator
Circulating Pump
Mixing Valve