Maintenace - Scale Flush Procedure
1 On-Demand Water Heater
G as S upply
V1
V3
V2
V4
H1
H2
H3
Circulating Pump
C old W ate r Line
Hot Wa ter Line
In-l n
i e
F ilter
Flush Procedure
1.  Disconnect electrical power to the water heater.
and V4).
3.  Connect pump outlet hose (H1) to the cold water line at service valve V2.
4.  Connect drain hose (H3) to service valve V1.
5.  Pour approximately 4 gallons of virgin, food grade, white vinegar or citric 
acid into pail.
6.  Place the drain hose (H3) and the hose (H2) to the pump inlet into the 
cleaning solution.
7.  Open both service valves (V1 and V2) on the hot water and cold water 
lines.
8.  Operate the pump and allow the cleaning solution to circulate through 
the water heater for at least 45 minutes.
10. Rinse the cleaning solution from the water heater by:
a.  remove the free end of the drain hose (H3) from the pail
11. Disconnect all hoses.
13. Restore electrical power to the water heater.
Key
Pressure Relief  Valve
Check Valve
3/4" Union
3/4" Ball  Valve
Boiler Drain Valve
Solenoid Valve
S
Pressure Regulator
Circulating Pump
Mixing Valve