Location Requirements
Site location
Select a location near the center of the water piping
system. It must be installed indoors and in a vertical
position on a level surface, in an area where water 
leakage will not cause consequential damage.
The water heater should be located in an area not
subject to freezing temperatures. Water heaters located
in unconditioned spaces (i.e., attics, garages, base-
ments, etc.) may require the water piping and drain 
piping to be insulated to protect against freezing. The 
drain and controls must be easily accessible for opera-
tion and service.
Keep combustibles such as boxes, magazines, clothes, 
etc., away from the water heater area.
Do not use this water heater in conjunction with a spa or 
hot tub.
IMPORTANT: The water heater should be located in 
an area where leakage of the tank or connections will 
not result in damage to the area adjacent to the water 
heater or to lower floors of the structure. Due to the 
normal corrosive action of the water, the tank will 
eventually leak after an extended period of time. 
Also, any external plumbing leak, including those 
from improper installation, may cause early 
failure of the water tank due to corrosion if not 
repaired. If the homeowner is uncomfortable with 
making the repair, a qualified person should be 
contacted. A suitable metal drain pan should be 
installed under the water heater as shown below. This 
metal drain pan is to protect the property from damage 
which may occur from normal condensate formation 
on the tank or leaks in the tank and pipe connections. 
The metal drain pan must limit the water level to a 
maximum depth of 2-1/2 inches and be two inches 
wider than the heater and piped to an adequate drain. 
Locate the water heater near a 
suitable indoor drain. Outdoor drains are subject to 
freezing temperatures which can obstruct the drain 
line. The piping should be at least 3/4”ID and pitched 
for proper drainage.
Under no circumstance will the manufacturer or 
seller of this water heater be held liable for any 
water damage that is caused by your failure to 
follow these instructions.
NOTE: Local codes and requirements in your area may
require the water heater to be installed such that the 
bottom element is elevated from the floor at least 18 
inches.
NOTE: The water heater shall be located so it is not 
subject to physical damage by moving vehicles or area 
flooding.
State of California 
NOTE: For installation, this water heater must be 
braced, anchored, or strapped to avoid falling or moving 
during an earthquake. Correct installation procedure in-
structions may be obtained from California’s Office of the 
State Architect. 1102 Q street, Suite 5100, Sacramento, 
CA 95811. Instructions can also be downloaded to your 
computer at www.dsa.dgs.ca.gov/Pubs.