H8908B HUMIDISTAT H8908C DEHUMIDISTAT
3
69-1341
WIRING
CAUTION
Personal Injury Hazard.
Power supply can cause electrical shock and 
injury.
Disconnect power supply before installation or 
servicing.
All wiring must comply with applicable local codes, ordi-
nances and regulations. Make wiring connections 
according to humidifier (or dehumidifier/ventilator) 
instructions, if available; otherwise, see typical wiring 
diagrams in Fig. 5 through 12.
IMPORTANT
Select models of fan centers include humidifer 
taps so the current sensing relay or sail switch 
is not needed. 
If not using a current sensing relay or sail 
switch, the humidifier must be energized dur-
ing blower motor cycles for proper operation. 
On multispeed blower applications, do not wire 
the high voltage side of the transformer to the 
same power source that services the furnace 
blower. Premature transformer burnout can 
occur. 
On HE360 fan powered humidifier models, 
only the two yellow wires are connected to the 
control. The remaining two red wires are only 
used with electronic humidity controls. 
Fig. 5. Typical wiring diagram for 
system with fan interlock.
Fig. 6. Typical wiring diagram for system 
with 2-speed fan motor.
Fig. 7. Typical wiring diagram of current 
sensing relay with humidifier.
Fig. 8. Typical wiring diagram 
of sail switch with humidifier.
Fig. 9. Typical wiring diagram for steam humidifiers.
Fig. 10. Typical parallel wiring of humidity controller 
with Chronotherm® IV Thermostat for 
dehumidification and mildew control.
1
1
2
PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION 
AS REQUIRED.
24 VAC WIRING. 
2
HUMIDIFIER
TRANSFORMER
FURNACE
FAN
MOTOR
H8908B
FAN CONTROL
L1
(HOT)
L2
M13368
POWER
SUPPLY
1
1
H
L
C
2
POWER SUPPLY.  PROVIDE DISCONNECT MEANS AND OVERLOAD 
PROTECTION AS REQUIRED.
24 VAC WIRING. 
2
HUMIDIFIER
TRANSFORMER
2-SPEED
FAN
MOTOR
DPST
SWITCHING
RELAY
H8908B
FAN CONTROL
L1
(HOT)
L2
M13384
POWER
SUPPLY
M13386
L1 
(HOT)
L2
1
2
1
2
POWER SUPPLY.  PROVIDE DISCONNECT MEANS 
AND OVERLOAD PROTECTION AS REQUIRED.
24V WIRING.
HUMIDIFIER
TRANSFORMER
WATER 
SOLENOID
LEAD WIRE
CURRENT
SENSING
RELAY
C
LO
HI
H8908B
M13385
L1 
(HOT)
L2
1
2
1
2
POWER SUPPLY.  PROVIDE DISCONNECT MEANS 
AND OVERLOAD PROTECTION AS REQUIRED.
24V WIRING.
HUMIDIFIER
TRANSFORMER
H8908B
SAIL
SWITCH
M13387
1
1
1
FOLLOW THE INSTALLATION INSTRUCTIONS 
INCLUDED WITH THE STEAM HUMIDIFIER 
TO WIRE THE SYSTEM FAN.
NOTE: 
HUMIDIFIER
H8908B
TO 
SYSTEM
FAN 
HUMIDISTAT
TERMINALS
FAN WIRING
TERMINALS
24V WIRING.
B
O
W
Y
G
R
HEATING
RELAY OR
VALVE COIL
COOLING
CONTACTOR
COIL
FAN
RELAY
COIL
CHRONOTHERM® IV THERMOSTAT
PROVIDE OVERLOAD PROTECTION AND
 DISCONNECT MEANS AS REQUIRED.
M13366
H8908C
1
1