Select NO for normal operation. Select YES 
to go to a special FLASH UPGRADE MODE 
that rewrites the operating software from 
a computer connected to the back panel 
COMPUTER I/O port. This feature should 
only be performed by qualifi ed personnel. 
We strongly recommend having your Rotel 
Dealer perform this upgrade.
NOTE
After performing the software upgrade, 
turn off the RSP-1069. Then, turn it back on 
to return to normal operation.
Zone 2–4 Setup
ODC:H:IJE
ODC:/ODC:'
HDJG8:/89
K>9:D>CEJI/8dbedh^iZ&
KDAJB:H:IJE/KVg^VWaZ
KDAJB:/+%
IJGCDCKDA/AVhi
B6MKDA/BVm
&'KIG><<:G/&T(TTT
B6>CB:CJ
The ZONE SETUP menu provides settings and 
confi guration options related to the operation 
of the remote zones. This menu is reached 
by highlighting the ZONE line on the MAIN 
menu and pressing ENTER.
ZONE: Specifies the zone to configure, 
ZONE 2, 3, or 4. Each zone is confi gured 
individually.
SOURCE: Specifi es a source for listening in 
the selected zone. Options are CD, TUNER, 
TAPE, VIDEO 1–5, SOURCE, and OFF. Se-
lecting the SOURCE option links the zone 
source to the source selected for the main 
zone so that the remote zone will hear the 
same source as the main zone. Selecting the 
OFF option turns the zone off.
VIDEO INPUT: Specifi es a video source 
(Composite Video only) for the selected 
zone. The options available are Composite 
1, 2 and 3 and OFF. (If SOURCE, above, is 
set to OFF, the VIDEO INPUT selection will 
not be available.)
VOLUME SETUP: confi gures the remote zone 
outputs for VARIABLE or FIXED volume levels. 
VARIABLE allows control of the volume settings 
in the remote zone from the RSP-1069 front 
panel or from a remote control/IR repeater 
in the zone. FIXED output disables the volume 
control. In this mode, the remote zone level 
can be fi xed at the level specifi ed on the next 
line, thus optimizing system performance when 
sending a fi xed level signal to a preamp or 
amplifi er with its own volume adjustment.
VOLUME: In VARIABLE output mode, this 
line shows the current volume setting for re-
mote zone. In FIXED output mode, this volume 
setting establishes a permanent fi xed output 
level for the remote zone.
Move the highlight to the desired line using 
the UP/DOWN buttons and use the +/– but-
tons to adjust the volume level. To return to the 
MAIN menu, press the ENTER button. Press the 
MENU/OSD button on the remote to cancel the 
display and return to normal operation.
TURN ON VOL: Specifi es a default volume 
level to be used each time the remote zone is 
activated. You can select LAST to have the zone 
activate with the last previously used volume 
setting. Or, you specify a volume from MIN 
(full mute) to MAX, in 1dB increments. Note 
that this setting cannot exceed the MAX VOL 
established in the next line of the menu.
MAX VOL: Specifi es the maximum volume 
level for the remote zone. The volume cannot 
be adjusted above this level. Settings range 
from MIN to MAX, in 1dB increments.
12V TRIGGER: The RSP-1069 has six 12V 
trigger outputs (labeled 1–6) that supply a 
12V DC signal to turn on Rotel components 
and other components as needed. This menu 
item turns on specifi c 12V trigger outputs 
whenever the indicated zone is activated. The 
six 12V Trigger outputs may be assigned to 
each Zone and can send a turn-on signal to 
remote components whenever the Zones are 
activated. For example, Zone 2 could use 12V 
Triggers 1, 3 and 6; Zone 3, 12V Triggers 2 
and 3; Zone 4, 12V Triggers 5 and 6.
1.  Press the +/– buttons on the remote to 
change the fi rst position from blank to 1 
(activating TRIGGER 1 for that zone).
2.  Press the ENT button on the remote to 
move to the next position.
3.  Repeat until all six positions are set as 
desired. A fi nal press of the ENT button 
confi rms the selection.
Default Setup
9:;6JAIH:IJE

;68IDGN9:;6JAI/Cd

JH:G9:;6JAI/Cd
H:IJH:G9:;6JAI/Cd
H:IC:LE6HHLDG9/CD
B6>CB:CJ
The DEFAULT SETUP menu provides access 
to three functions:
•  Restore all features and settings to the 
original FACTORY DEFAULT settings. 
•  Memorize a custom group of settings as 
a USER DEFAULT. This requires entering 
a password.
•  Activate the USER DEFAULT settings.
•  Change the password.
To restore the FACTORY DEFAULT set-
tings:
 Place the highlight on the FACTORY 
DEFAULT line using the UP/DOWN buttons 
and use the +/– buttons to change the set-
ting to YES. Press the ENTER button to pro-
ceed with resetting the FACTORY DEFAULT 
settings. The unit will power off and then on, 
with the factory settings restored. To return 
to the MAIN menu without resetting the FAC-
TORY DEFAULT settings, change the entry to 
NO and press the ENTER button.
NOTE
Resetting to factory default settings 
will erase all stored settings including delay 
settings, speaker settings, balance settings, 
input settings and more. You will lose ALL 
system confi guration settings. Be certain that 
you wish to do so before resetting the fac-
tory defaults.
To memorize USER DEFAULT settings: 
Many of the current confi guration settings 
can be stored as a USER DEFAULT, which 
can be activated at any time from this menu 
screen. To save the current settings as a 
USER DEFAULT:
1.  Place the highlight on the SET USER DE-
FAULT line using the UP/DOWN buttons 
and use the +/– buttons to change the 
setting to YES. 
2.  Press the ENTER button to go to confi rma-
tion screen where a password must be 
entered. The default password is 8888.