Classe Audio CA-2100 用户手册

下载
页码 24
20
Troubleshooting
In general, you should refer any service problems to your Classé dealer. Before 
contacting your dealer, however, please check to see if the problem is listed here.
1.  No sound, and no Channel LED is lit.
•  The amplifier is not plugged into the AC mains, or the AC 
mains are down (circuit breaker, fuse).
•  A brown-out or short-term loss of power might require the 
internal microprocessor to be reset. Unplug the unit for at least 
30 seconds and then plug it in again and try powering it up.
•  The AC mains fuse is blown. See Troubleshooting #4, below (or 
contact your Classé dealer).
•  The AC mains  is out of range. Check the voltage specified on 
the rear panel.
2.  No sound, and one or more Channel LEDs is blinking red.
•  Your protection circuitry may have been engaged. Disconnect 
the amplifier from the AC mains, and disconnect all inputs and 
outputs.
•  Then try to power up the amplifier again, connecting it only 
to AC power. If the LED continues to blink, there is a fault 
condition in the amplifier itself, and it should be disconnected 
and taken to your Classé dealer for service.
•  If it powers up without any difficulty, power it back down and 
reconnect only the inputs. Then restart the amplifier. If it goes 
into its blinking protection mode, something is wrong with a 
component “upstream” of the amplifier—probably a DC offset 
or similar problem. Your amplifier is trying to protect your 
loudspeakers (even small amounts of DC can damage woofers in 
relatively little time). Try different source components to discover 
whether the problem is limited to a single source, or exists all the 
time (which would indicate a problem with the preamplifier). 
Contact your dealer for help with the appropriate component.
3.  The amplifier keeps shutting off.
•  Make sure you are providing adequate ventilation to the 
amplifier, and that the ambient room temperature is below 
105°F (40°C).
•  Run through the troubleshooting sequence outlined above 
(assuming the amplifier is going into its protection mode).