Lucent Technologies Release 7 用户手册

下载
页码 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-521
DIOD-DS1 (DS1 DIOD Trunk) 
9
Notes:
a. Error Type 1—Aux Data 57408
No tip ground is detected on an outgoing 
call.
Aux Data 57476—Rotary Dial before Wink.
Aux Data 57477—Rotary Dial pulse too early.
Aux Data 57485
Wink too short for a valid signal.
Aux Data 57487
PBX could not get ‘‘loop close’’ signal.
The DS1 Interface circuit pack detected a hardware fault. These errors will 
cause the Dial Tone Test (#314) to run and are only considered a problem 
if the Dial Tone Test fails (in which case Error Type 1025 will also show up). 
In this case, the trunk may be put in the ready-for-service state (shown as 
‘‘disconnected’’ by the status command), which allows only incoming 
calls. Run the Dial Tone Test (#314) and follow the procedures.
b. Error Type 15—This is a software audit error that does not indicate any 
hardware malfunction. Run Short Test Sequence and investigate 
associated errors (if any).
c. Error Type 18—System Technician has busied out the trunk to the 
out-of-service state. No calls can be made on this trunk except the Facility 
Access Test Call. For details on this feature, refer to ‘‘Facility Test Calls’’ 
section in Chapter 6.
d. Error Type 130—This error type indicates that the circuit pack has been 
removed or has been insane for more than 11 minutes. To clear the error, 
reinsert or replace the circuit pack.
e. Error Type 257—The DS1 Interface circuit pack detects a hardware fault. 
Aux Data 57392 indicates no external release on PBX disconnect. 
2305(k)
50944
2562(l)
16665
2817(m)
52992
3840(n)
Port Audit and 
Update Test (#36)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
This alarm is only raised when the System-Parameter Country form has the Base Tone Generator
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group
are out of service, then the alarm will be upgraded to a MAJOR alarm.
3.
Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
DS1 
DIOD
 Trunk Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value