Lucent Technologies Release 7 用户手册

下载
页码 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1158
PDATA-PT (Packet Data Line Port) 
9
System Port Connectivity Test (#603)
This test is destructive.
This test verifies the capability to communicate between the PDATA and the Data 
Line (TN 726B) ports of a System Port member. A System Port requires the 
PDATA port and the Data Line port to be wired together. Failure of this test may 
indicate faults with the wiring on PDATA port. Thus an off-board alarm is raised.
Since this test is applicable only to ports that are configured as a System Port, 
the switch aborts the test if the port is not configured as a System Port.
The switch aborts this test if calls associated with the port are in progress. If the 
ports are in use but tests must be run, the port can be busied out using the 
busyout port UUCSSpp command. Release the port when the tests are done. If 
a problem is fixed, the associated alarms will not be resolved until the port is 
released.
Table 9-460.
TEST #603 System Port Connectivity Test
Error 
Code
Test 
Result
Description/ Recommendation
11
ABORT
The Data Line port could not be setup for this test.
2100
ABORT
Could not allocate Data Line resources
1. Determine the Data Line port associated with the PDATA port.
2. Run test port UUCSSpp. If any of the Data Line port tests fail, resolve 
these problems first.
3. If the problem persists, check the port admin and wiring
4. Verify that the Data Line port is not busied out (status data-module 
extension) or not installed.
1000
ABORT
The PDATA or Data Line port is in use for a call or maintenance tests are 
already running on these ports.
1. Retry the command when the port is idle. The port may be forced to the 
idle state by executing the busyout port UUCSSpp command. This 
command is destructive causing all calls and links associated with the port 
to be torn down.
1005
ABORT
The configuration for this test is incorrect.
1. This is the expected test result for PDATA ports which have not been 
administered as a System Port.
2. If the PDATA port is supposed to be configured as System Port, make the 
necessary modifications on the port administration form change 
data-module extension
.
Continued on next page