DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1338
PRI-CDR/SEC-CDR (Call Detail Recording Link) 
9
Error Log Entries and Test to Clear Values
Notes:
a. The CDR link is busied out. The CDR link is torn down.
b. Link Retry Test (#215) fails. An error was detected when setting up the link. 
Refer to the preceding section ‘‘Procedures for Restoring the CDR Link’’ 
for resolution.
c. The CDR physical link is down for one of the following reasons:
Cable to the CDR output device is disconnected.
CDR output device is powered off.
The data extension where the CDR output device connects to has 
been busied out or there is a scheduled daily interchange.
Check the connectivity of wire and cable among wall jacket, data module, 
and the CDR output device. Enter status data extension and verify that 
the data extension of the CDR output device is in the in-service/idle state. 
If the data extension is not available, then refer to The preceding section 
‘‘Procedures for Restoring the CDR Link’’ for resolution. Issue the display 
system-parameters-maintenance
 command to see the start time of daily 
maintenance. If the error occurs and is resolved during of daily 
maintenance, it can be ignored.
Table 9-523.
CDR Link Maintenance Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
0
Any
Any
Any
test cdr primary|secondary 
sh
18(a)
0
busyout cdr 
primary|secondary
WARNING
OFF
release cdr 
primary|secondary
257(b)
Any
Link Retry Test (#215)
MINOR/
2
 
WARNING
2.
Minor alarms may be downgraded to Warning alarms based on the value used in the set options 
command.
OFF
test cdr primary|secondary 
l
513(c)
test cdr primary|secondary
1025(d)
1281(e)
Any