DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1798
TONE-PT (Tone Generator) 
9
Error Log Entries and Test to Clear Values
Notes:
a. A failure in the tone generation facility on the indicated circuit pack has 
been detected. Replace the circuit pack. Se
Tone-Clock Circuit Pack in the TONE-BD section.
b. The indicated Tone-Clock circuit pack has been made unavailable via the 
busyout tone-clock UUC command. It only applies to systems which 
have the High or Critical Reliability Option administered, because only a 
standby Tone-Clock circuit pack may be made busy by that command. To 
resolve this error, execute the release tone-clock UUC command for the 
alarmed circuit pack.
c. This error type indicates that the circuit pack has been removed or has 
been insane for more than 11-minutes. To clear the error, reinsert or 
replace the circuit pack.
Table 9-671.
Tone Generator Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test tone-clock UUC r 1
1(a)
17664
Tone Generator Audit/
MAJOR/
ON
test tone-clock UUC r 2
Update Test (#41)
MINOR
2
2.
MAJOR alarm if the alarmed Tone-Clock circuit pack is not duplicated; MINOR if it duplicated within
the same Port Network.
18(b)
0
busyout tone-clock 
UUC
WARNING
OFF
release tone-clock UUC
130(c)
 
None
MINOR
ON
test tone-clock UUC Sh
257(d,f)
17667
None
MINOR
ON
513(e,f)
17666
Tone Generator Audit/ 
Update Test (#41)
MINOR
ON
test tone-clock UUC r 3
769
Any
Transmission Test 
(#40)
MAJOR/ 
MINOR
2
ON
test tone-clock UUC r 3
1025
Crosstalk Test (#90)
MAJOR/ 
MINOR
2
ON
test tone-clock UUC l r 2
1281(g)
Any
Tone Generator Audit/ 
Update Test (#41)
MINOR
ON
test tone-clock UUC r 3