Lucent Technologies Release 7 用户手册

下载
页码 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-332
test ds1-loop 
8
Help Messages
If the system technician presses HELP after entering “test ds1-loop” the following 
message will be displayed:
 Enter DS1 board location, 
[’cpe-loopback-jack-test-begin [number-of-bits bit-pattern]’ or
’far-csu-loopback-test-begin’ or’one-way-span-test-begin’ or
   ’end-loopback/span-test’ or’inject-single-bit-error’ or
    ’ds1/csu-loopback-tests’]
Error Messages
If the format for the board location is incorrect, the following error message will 
be displayed:
Port/Board invalid
If the EPN in which the specified board resides is not available, the following 
message will be displayed:
EPN is not available
If the specified board is not inserted in the system, the following message will be 
displayed:
 Board not inserted
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
 Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
 All maintenance resources busy; try again later
If the test ds1-loop command is executed and the “G3 Version” field on the 
“system-parameters customer-options” form is not V3 or later, then the following 
message will be displayed:
 G3 Version must be V3 or later
If the test ds1-loop command is executed on a circuit pack other than TN464F or 
TN767E or later DS1 board, then the following message will be displayed:
 Command valid for TN464F or TN767E or 
later release DS1 circuit packs