DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-43
Emergency Transfer Units and Associated Telephones 
5
Install Telephone for Power Transfer Unit
Trunk/Auxiliary Field: Telephone Used Only for Emergency Transfer
1. Connect a pair of wires between the -48V and GRD terminals on the 
yellow emergency transfer row/connecting block and the EM TRANS 
RELAY PWR
 terminal. See 
2. Connect CO trunk leads from the purple field to TC terminals on the yellow 
emergency transfer row/connecting block for each trunk.
3. Connect CO trunk leads from the green field to TK terminals on the yellow 
emergency transfer row/connecting block for each trunk.
4. Connect ST leads on the yellow emergency transfer row/connecting block 
for each emergency transfer telephone to the ST terminal appearance in 
the yellow trunk/auxiliary field. The ST terminal leads should be terminated 
on the following pairs: 1, 4, 7, 10, 13, 16, 19, or 22 (the first pair of any 
3-pair group).
5. Connect the ST leads from the terminal in Step 4 to the assigned terminal 
in the blue or white station distribution field.
Trunk/Auxiliary Field: Telephone Used for Emergency Transfer and as 
Normal Extension
1. Connect a pair of wires between the -48V and GRD terminals on the 
yellow emergency transfer row/connecting block to the EM TRANS 
RELAY PWR
 terminal. See 
.
2. Connect CO trunk leads from the purple field to TC terminals on the yellow 
emergency transfer row/connecting block for each trunk.
3. Connect CO trunk leads from the green field to TK terminals on the yellow 
emergency transfer row/connecting block for each trunk.
4. Connect telephone leads from the purple analog line board row/ 
connecting block to the LC terminals on the yellow emergency transfer 
row/connecting block for each telephone.
5. Connect ST leads on the yellow emergency transfer row/connecting block 
for each emergency transfer telephone to the ST terminal appearance in 
the purple trunk/auxiliary field.
6. Connect the ST leads from the terminal in Step 4 to the assigned terminal 
in the blue or white station distribution field.
Telephone Installation
Install telephone assigned to emergency transfer as follows:
1. Connect telephone to the information outlet.
2. Install patch cords/jumper wires between the system side and the station 
side of the station distribution field on the MDF.