Lucent Technologies Release 6 用户手册

下载
页码 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Connect Cabinets 
Page 1-33
Fiber Optic Interconnect Cabling 
1
Critical Reliability
Figure 1-13
 shows typical fiber optic cabling between cabinets. The cable 
between port slots 1 and 2 on each switch node is a metallic cable (H600-278). 
1. Connect the 2 groups of 1 to 15 cables between the PPN and each EPN in 
an alternating port slot order: 20, 3; 19, 4; 18, 5; and so forth.
Figure 1-13.
Critical-Reliability CSS-Connected with 1 Switch Node
2. Both connections from each EPN must go to the same slot number. For 
example: EPN cabinet 2, 2A1 to 1E3 and cabinet 2, 2B2 to 1D3.
Figure Notes
1. Cabinet 1 (PPN with 1 Duplex Switch 
Node)
2. Cabinet 2 through 16 (EPN)
3. H600-278 Metallic Cable
4. To other EPNs