4.3
Alarm and relay connector
Figure 4.4
Alarm and relay connector pins
Max. wire diameter AWG 22-28 for both stranded and 
solid; cut back 5 mm (0.2 in) of insulation.
Alarm output relay switching capability: Max voltage 30VAC 
or +40 VDC. Max 0.5 A continuous, 10 VA.
Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled 
with 22 kOhm pull-up to +3.3 V.
Alarm in: configurable as active low or active high.
Max. 42 V allowed between camera ground and each of the 
relay pins.
Pin
Alarm socket
1
Alarm in 
2
not  used
3
Relay out contact 2
4
Alarm in ground
5
not  used
6
Relay out contact 1
ALARM
1
2
3
4
5
6
5 mm 
(0.2 in)