4.3
Alarm and relay connector
Figure 4.4
Alarm and relay connector pins
–
Max. wire diameter AWG 22-28 for both stranded and
solid; cut back 5 mm (0.2 in) of insulation.
–
Alarm output relay switching capability: Max voltage 30VAC
or +40 VDC. Max 0.5 A continuous, 10 VA.
–
Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled
with 22 kOhm pull-up to +3.3 V.
–
Alarm in: configurable as active low or active high.
–
Max. 42 V allowed between camera ground and each of the
relay pins.
Pin
Alarm socket
1
Alarm in
2
not used
3
Relay out contact 2
4
Alarm in ground
5
not used
6
Relay out contact 1
ALARM
1
2
3
4
5
6
5 mm
(0.2 in)