4. MAINTENANCE 
ENGLISH VERSION EO1-33056 
4.1 Cleaning
 
E4- 2 
4.1.1 Print Head/Platen 
(Cont.) 
 
 
 
 
 
 
 
 
4.1.2 Pinch Roller 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
7.  Wipe the Platen with a soft cloth slightly moistened with absolute  
 ethyl 
alcohol 
 
 
 
1.  Turn off the power and unplug the printer. 
2.  Set the Head Lever to the “OPEN” position. 
3.  Open the Top Cover and Right Side Cover. 
4.  Open the Head Lock Plate. 
5.  Turn the Pinch Roller Lever clockwise to release the Pinch Roller. 
 
6.  Remove the ribbon and media from the printer. 
7.  Set the Head Lever to the Position 2.  
8.  
Remove the White Screw and detach the Ribbon End Sensor Plate in 
the direction of the arrows.  
 
 
 
 
Platen
Pinch Roller Lever
White Screw 
Ribbon End Sensor 
Plate 
Ribbon End Sensor 
Plate 
1
2
CAUTION!
 
Do not pull hard on the Ribbon 
End Sensor Plate.  Doing so 
may damage the Ribbon End 
Sensor Harness, causing a 
printer failure. 
NOTE: 
Be sure to set the Head Lever to 
Position 2, otherwise the Pinch 
Roller cannot be removed. 
 
 
 
Position 2 
Head Lever