viii  
 
GUIDE TO INSTALLATION 
 
 
The following can be used as a checklist to verify all of the steps necessary for 
complete installation of the Matrix-1000
 compact 2D reader. 
 
1)  Read all information in the section "Safety Precautions" at the beginning of this 
manual. 
 
2)  Correctly mount the reader using the bracket provided (sub-pars. under 2.2). 
 
3)  Position the reader at the correct reading distance according to your model 
 
4)  Make electrical connections to your Matrix-1000™ reader by either: 
a) 
Connecting the test cable to the Matrix-1000™ reader (par.2.4). 
b) 
Providing correct and complete system cabling according to the signals        
necessary for the layout of your application. 
• 
Layout: Point-to-point or Multidrop, etc. (sub-pars: 2.6); 
• 
Cabling: Power, Main RS485, Auxiliary RS232, External Trigger Input 
 
5)  Configure the Matrix-1000™ reader by installing and running VisiSet™ from the 
CD-ROM provided onto the configuration PC (pars. 3.1, 3.2, 3.3). See the 
Rapid Guide to Configuration in the VisiSet™ Help On Line. The main steps 
are: 
a) 
Select the codes to be read 
b) 
Set-up the communication parameters 
c) 
Define data formatting parameters 
d) 
Fine tune your Matrix-1000™ reader using the VisiSet™ Calibration Tool 
 
Specific VisiSet™ parameter details are also available in the Help On Line. 
 
6)  Exit the configuration program and run your application. 
 
 
The installation is now complete.