5 TROUBLESHOOTING 
 
 
5.1 GENERAL 
GUIDELINES 
 
• 
When wiring the device, pay careful attention to the pin number of the signals 
and whether you are referring to the 25-pin connector or to the C-BOX 100 
spring clamp connectors. 
• 
If you need information about a certain reader parameter you can refer to the 
VisiSet
 program help files. Either connect the device and select the parameter 
you’re interested in by pressing the F1 key, or select Help/Contents/Matrix 
Configuration
 from the command menu. 
• 
If you’re unable to fix the problem and you’re going to contact your local 
Datalogic office or Datalogic Partner or ARC, we suggest providing (if possible): 
Application Program version, Parameter Configuration file, Serial Number and 
Order Number of your reader. You can get this information while VisiSet™ is 
connected to the reader: the Application Program version is shown in the 
Terminal Window; the Parameter Configuration can be saved on a .ini file 
applying the File/Save pars to file command in the Parameter Setup window; 
Serial Number and Order Number can be get applying the respective command 
in the Tools menu. 
 
TROUBLESHOOTING GUIDE 
Problem Suggestion 
Power ON: 
the “PWR” LED is not lit. 
• 
Is power connected? 
• 
If using a power adapter (like PG6000), is it 
connected to wall outlet? 
• 
If using rail power, does rail have power? 
• 
If using C-BOX 100, does it have power (check 
switch and LED)? 
• 
Check if you are referring to the 25-pin 
connector or to the C-BOX 100 spring clamp 
connectors. 
• 
Measure Voltage either at pin 13 and pin 25 (for 
25-pin connector) or at spring clamp 1 and 2 (for 
C-BOX 100). 
After Power ON: 
the "READ" LED is lit or 
blinking without any code 
in front of the reader and 
the connection to VisiSet™ 
fails. 
• 
Contact your local Datalogic office or Datalogic 
Partner or ARC.