Toshiba e-STUDIO451c 用户手册
![Toshiba](https://files.manualsbrain.com/attachments/acaaaa9cc6b763ccfc72ced2ae95d9c94b8b8632/common/fit/150/50/8adbcbcd45c75dc53932fc9caf6f2740daed52d836b76efbd0162ac2599f/brand_logo.png)
e-STUDIO281c/351c/451c ADJUSTMENT
June 2005 © TOSHIBA TEC
3 - 2
3.2
Adjustment of the Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
(1) Install the cleaner and developer unit.
Note:
Note:
Do not install the toner cartridge.
(2) While pressing [0] and [5] simultaneously, turn the power ON. The following message will be dis-
played.
(3) Key in a code and press the [START] button.
(4) Adjustment for “K” (Magnetometric sensor control)
• The following message will be displayed approx. 2 minutes later.
Code
200: All developer materials 201: Developer material Y 202: Developer material M
203: Developer material C
203: Developer material C
204: Developer material K 206: Developer material Y, M, C
100%
A
A3
TEST MODE
[0] [5]
[POWER]
[POWER]
100%
200
A3
TEST MODE
(Code)
[START]
K: xxxV
K: zzzV
(B)
(C)
(A)
(B): Current sensor voltage (V)
(C): No display
(A): Target values (V) for adjustment reference
voltage
(C): No display
(A): Target values (V) for adjustment reference
voltage