e-STUDIO281c/351c/451c ADJUSTMENT
June 2005 © TOSHIBA TEC
3 - 46
3.7.9
Fine adjustment of black density
The density of black side on scanned image is adjusted at color-scanning.
<Adjustment Mode (05)>
Note: 
Note: 
Be careful for the value not to be too large since the gradation is reproduced worse in darker 
side.
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in the codes and press the [START] button.
(3) Key in the adjustment values. Acceptable values : 0 to 4. (To correct the value once keyed in, 
press [CLEAR] button.)
(4) Press the [ENTER] or [INTERRUPT] button to store the value in memory. ? The equipment goes 
back to the ready state.
(5) Let the equipment restart and perform scanning job.
(6) If the desired image has not been attained, repeat step (1) to (5).
3.7.10
RGB conversion method selection
The color space conversion method of image is decided at color-scanning.
<Adjustment Mode (05)>
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in the codes and press the [START] button.
(3) Key in the adjustment values. Acceptable values : 0 to 3. (To correct the value once keyed in, 
press [CLEAR] button.)
(4) Press the [ENTER] or [INTERRUPT] button to store the value in memory. ? The equipment goes 
back to the ready state.
(5) Let the equipment restart and perform scanning job.
(6) If the desired image has not been attained, repeat step (1) to (5).
Code
Original mode
Remarks
1075
Text
The larger the value is, the black side of the image becomes darker.
Acceptable values: 0 to 4 (Default: 0)
1076
Printed Image
1077
Photo
Code
Original mode
Remarks
1080
Text
Remarks
0: sRGB, 1: AppleRGB, 2: ROMMRGB, 3: AdobeRGB 
(Default: 0)
1081
Printed Image
1082
Photo