Toshiba FC-210 用户手册

下载
页码 254
February 2002  ©  TOSHIBA TEC
2 - 7
FC-210/310  ADJUSTMENT
2.3  Adjustment of Image Quality Control
(1)
At the time of unpacking
Prior to image dimensional adjustment, perform the “Automatic initialization of image quality control
(05-879)” procedure.
(2)
When any of the following parts is replaced, be sure to perform the  “Automatic initialization of image
quality control (05-879)” procedure.
• Processing unit (EPU)
• Transfer belt unit (TBU)
• Photoconductive drum
• Developer material
• Laser optical unit
• Image quality sensor
Note: When performing "Automatic gamma adjustment" in addition, “Automatic initialization of image quality
control” should be done first.
(3)
When performing "Automatic gamma adjustment" in cases other than the above ones, do the  “Forced
performing of image quality control (05-878)” procedure before "Automatic gamma adjustment".
Code
Adjustment item
Contents
878
Forced performing of
<Procedure>
image  quality  control
(1) While pressing [0] and [5] simultaneously, turn the power ON. 
Adjustment mode
(2) Enter [878] with digital keys and press the [START] key.
(3) When the adjustment finishes normally, the copier will return to
the adjustment mode’s initial state.
If an error has occurred, take appropriate action by referring to
“4. TROUBLESHOOTING”.
879
Automatic initialization of
<Procedure>
image  quality  control
(1) While pressing [0] and [5] simultaneously, turn the power ON. 
Adjustment mode
(2) Enter [879] with digital keys and press the [START] key.
(3) When the adjustment finishes normally, the copier will return to
the adjustment mode’s initial state.
If an error has occurred, take appropriate action by referring to
“4. TROUBLESHOOTING”.