3M Touch Systems, Inc. Proprietary Information – 37531 Rev D
Table 10. Data Stage (controller response) 
Offset 
Field 
Size 
Value 
Description 
Report ID 
0x12 
Feature Report ID  
Max Count 
0x1E 
Number of actual 30 fingers 
supported 
Note:  The number of actual contacts reported may exceed this number (possibly up to 
60). 
Set Feature - Reset  
This is a request to perform a controller reset. Soft resets are automatic after any block 
parameter changes. 
Table 11. Reset - Setup Stage 
Offset 
Field 
Size 
Value 
Description 
0 bmRequestType 
0x21 
Class,H2D,Interface 
1 bRequest  1 
0x09 
Set 
Report 
2 wValue 
0x0303 
msb=03=Feature 
 
lsb=03= Feature Report ID  
4 wIndex 
0  Always 
6 wLength 
8  Always 
Table 12. Reset – Data Stage 
Offset 
Field 
Size 
Value 
Description 
Report ID 
0x03 
Feature Report ID 
Report Subtype 
1  
0x07 
Indicates a reset request 
2 bResetType 1 
0x01 
0x02 
Soft Reset 
Hard Reset 
3--7  
5  0 
Not 
used 
A Hard Reset will cause the controller to re-enumerate. 
In the case of a Soft Reset, after sending the command, the controller will acknowledge 
(ACK) the transfer, but the command will not yet be completed. Before sending any 
other commands, the host should poll with GetStatus until the command status field 
returns “Soft Reset Occurred,” “Command Complete,” or “Fail”.  Any timeout for this 
status polling should be 2 seconds minimum.