Hitachi Ultrastar 15K450 (FC-AL) Hard Disk Drive Specification
41
12.0  Vibration and Shock
All vibration and shock measurements in this section are made with a bare drive.  The input for the measurements are applied 
to the normal drive mounting points unless noted otherwise.
12.1  Operating Vibration
12.1.1  Random Vibration
The drive is designed to operate without unrecoverable errors while being subjected to the vibration levels as defined below. 
The assessments are carried out during 30 minutes of random vibration using the power spectral density (PSD) levels as fol-
lows.
 No Errors:
 0.4 G RMS, 5-500 Hz, flat PSD profile for each of the three mutually perpendicular axes.
 No Data Loss: 1.2 G RMS, 5-500 Hz, flat PSD profile for each of the three mutually perpendicular axes.
Note:
 The specified levels are measured at the mounting points.
12.1.2   Swept Sine Vibration
The drive will meet the criterion while operating in the respective conditions as described below.
 No errors: 
0.5 G 0-peak, 5-400-5 Hz sine wave, 0.5 octave/minute sweep rate                                                            
 No data loss:
1.5 G 0-peak, 5-500-5 Hz sine wave, 0.5 octave/minute sweep rate
12.2  Non-operating Vibrations
The drive will not sustain permanent damage or loss of recorded data after being subjected to the environments as described 
below.
12.2.1   Random Vibration
The test consists of a random vibration applied for each of the three mutually perpendicular axes at a time duration of ten min-
utes per axis.  
1.04 G RMS, 5-500 Hz, flat PSD profile
12.2.2   Swept Sine Vibration
The test consists of a swept sine vibration applied for each of the three mutually perpendicular axes.
 2.0G 0-peak, 5-500-5 Hz sine wave, 0.5 octave/minute sweep rate
12.3   Operating shock
The drive will meet the criterion while operating in the respective conditions as described below.  
 No data loss:       15G, 11 ms duration, half sinewave shock pulse      
 No data loss:       30G,   2 ms duration, half sinewave shock pulse
The shock pulses of each level are applied to the drive, ten pulses for each direction and for all three mutually perpendicular 
axes.  There must be a minimum of thirty seconds delay between shock pulses.  The input level is applied to a base plate where 
the drive is attached using four mounting screws.