Emerson MITX-430 用户手册
![Emerson](https://files.manualsbrain.com/attachments/1ef3aaad462e024fde6cecf537a4c6c781334d44/common/fit/150/50/6dab323528eefa0342baa74a10c15551c3b956250cf9d62f2117dcdf42a7/brand_logo.jpeg)
Operation
MITX-430/MITX-440-DVI-2E Installation and Use Guide (6806800K37B)
97
5.5.2.3
PEI Beep Codes
0xF3
Recovery firmware image found.
0xF4
Recovery firmware image loaded.
0xF5 - 0xF7
Reserved for future AMI progress codes.
Recovery Error Codes
0xF8
Recovery PPI is not available.
0xF9
Recovery capsule is not found.
0xFA
Invalid recovery capsule.
0xFB - 0xFF
Reserved for future AMI error codes.
Table 5-33 PEI Status Codes (continued)
Status Code
Description
Table 5-34 PEI Beep Codes
# of Beeps
Description
1
Memory not Installed.
1
Memory was installed twice (InstallPeiMemory routine in PEI Core called
twice).
twice).
3
DXEIPL was not found.
3
DXE core firmware volume was not found.
7
Reset PPI is not available.
4
Recovery failed.
4