Emerson 752I 用户手册

下载
页码 172
CT Bus Interface:
 Signal Control
13-3
Figure 13-1:
Typical System Clocking Model
SIGNAL CONTROL
752i supports control signals that allow a PTMC site to master the CT clocks 
and/or data. The control registers are located in the Hot Swap Logic (HSL) programmable 
logic device (PLD) at hex address F821,0003
16
. The 750GL processor can access these reg-
isters. The following table summarizes the direction control registers:
Table 13-1:
CT Clock Control Registers
Register:
Bit:
Reset 
Value:
T8110 Not Installed 
(option 1):
T8110 Installed 
(option 2):
NETREF1_DIR
0
1
Controls direction of NETREF (on J4):
1=Katana
is NETREFx slave 
(input)
752i is NETREFx master 
(output)
These bits are not used.
NETREF2_DIR
1
1
C8_FRAME_A_TERM
2
1
Controls termination of FRAME and C8 data signals (on J4):
1=Katana
752i is not clock master (33 ohm series 
termination)
752i is clock master (no series termination)
Controls termination on clock signals:
1=33-ohm series termination present
0=no termination
C8_FRAME_B_TERM
3
1
Primary
Master
Secondary
Master
Bits
Derived
Source
Slave
Digital
Trunk
Card
Slave
Digital
Trunk
Card
CT_C8_A/CT_FRAME_A
CT_C8_B/CT_FRAME_B
CT_NETREF_1
CT_NETREF_2