Appendix D: RS-422/485 Line Interface 
Titan/cPCI adapters Electrical Interface Selection 
The Titan/cPCI adapter provides jumper selectable RS-232 and RS-422/485 electrical interfaces 
on each port. 
 
Jumper block JB sets the electrical interfaces for the individual ports.  Jumpers installed across 
the pins on jumper block JB enable the RS-232 interface for that port, while jumpers not 
installed across pins enable the RS-422/485 interface for that port.  
 shows the location 
of jumper block JB. 
 
Technical Tip 
Please refer to the README files on the driver diskettes for technical 
tips or release notes concerning installation and configuration of 
various device drivers and software utilities.  If you require further 
information please contact Connect Tech Technical Support 
 
Example 1 
This example shows the settings on jumper block 
JB so that port 2 is set for RS-232 and ports 1, 3, 
4 are set for RS-422/485.
 
 
 
JB 
Jumper Legend 
Jumpers on = RS-232 
enabled 
Port 1
Port 2
Port 3
Port 4
4 port models only
JB0
JB1
JB2
JB3
 
Example 2 
This example shows the settings on jumper block 
JB so that ports 1 & 2 are set for RS-422/485 
and ports 3 & 4 are set for RS-232. 
 
 
JB 
Jumper Legend 
Jumpers on = RS-232 
enabled 
Port 1
Port 2
Port 3
Port 4
4 port models only
JB0
JB1
JB2
JB3
 
Technical Note: 
You can set up the RS-232 serial ports to run at up to 230.4 
Kbps, but you must use good quality serial cables with lengths 