Telect T3 用户手册

下载
页码 20
DNI-3 User Manual
Installation
Issue A Rev 2
108469
Telect, Inc.
2-3
I
NSPECTION
Compare the contents of the DNI-3 shipping container with the packing 
list. Call Telect if you are missing anything.
NOTE
Telect is not liable for shipping damage.
If the shipping container is damaged, keep it for the carrier’s inspection.
Notify the carrier and call Telect’s Customer Service Department:
1-800-551-4567 or 1-509-926-6000
Keep the container until you have checked equipment operation. If you ex-
perience any kind of problem, call Telect’s Customer Service Department.
Use the original, undamaged container if you are instructed to return the
DNI-3 to Telect.
I
NSTALLATION
 P
ROCEDURE
Step
Action
1.
Align the DNI-3 chassis mounting holes with the mounting holes of 
the network bay.
2.
Insert four 24 x 1/2" mounting screws (two on each side) into the 
mounting holes and securely tighten them.
3.
Route the DCS IN cables to one side of the network bay. Tie-wrap 
the cables in place within the extender panel cable management 
brackets.
4.
Starting at the lowest DNI-3 panel and working  upward, connect 
the DCS IN cables to the NE-1 IN termination points on the rear of 
the DNI-3 panels.
5.
Secure the DCS IN cables to the wire management tray via the tie-
down slots.
6.
Route the DCS OUT cables to the opposite side of the network bay. 
Tie-wrap the cables in place within the extender panel cable man-
agement brackets.