RuggedRouter
 User Guide
Configuring End To End Backup
Figure 40: End To End Backup
This menu allows you to display and configure end to end backup.  
In order to start end to end backup at each and every boot, you must enable it via the 
System folder, Bootup And Shutdown menu.  The menu will remind you if the 
feature is not enabled.
The Primary Interface field determines the primary interface.  The interface selected 
should be configured to supply the default gateway.
The Peer IP Address on Primary field sets the IP address to probe for connectivity 
on the primary interface.
The Secondary Interface field determines the secondary interface.  
The Peer IP Address on Secondary field sets the IP address to probe for 
connectivity on the secondary interface.
The Fail Over Timer field determines the amount of time the primary link must be 
failed before directing packets down the secondary link.
The Generate Alarms field determines whether alarms are generated upon 
configuration problems and link failures.  
The Save button will save changes to the configuration file.   The Save and Apply 
button will save changes restart the end to end backup daemon. 
Current Routing & Interface Table 
This menu displays the current routing table and the state of the router's interfaces. 
Consult the Network Utilities chapter for details of this menu. 
56                                                                                                                                       RuggedCom