5.  When you are finished using Remote Console, close the browser window.  
6.  Repeat the steps in this section to connect to and manage other nodes via in-band KVM 
interfaces. 
Managing Node Power via an In-Band Power Interface 
You can power on, power off, recycle power, or gracefully shutdown a node via an associated in-
band power interface. Graceful shutdown allows the node to complete any processes it is 
currently running, while not allowing any new processes to begin, so that the node can shutdown 
without interrupting anything. 
1.  In the Nodes tree, select the node you want to manage through an in-band power interface. 
The Node Profile screen appears. The figure below shows an HP iLO/RILOE-enabled node 
with an in-band iLO-RILOE power control interface. 
 
Figure 17 Node Profile Screen, In-Band Power Interface 
2.  In the Node Profile screen, all configured interfaces display in the Interfaces section.  
3.  In the Name column, click the hyperlink of the in-band power interface you want to use to 
control power to the node. The Power Control screen appears. 
 
Figure 18 Power Control Screen, iLO/RILOE 
4.  The selected node’s name displays in the Node field.