TOSHIBA G3 APPLICATION GUIDELINE 21.5
*
For additional assistance, please contact Toshiba at (800) 231-1412 and ask for inverter marketing
Direction Change with RX Input (page 2 of 2)
Connections for bipolar reference
TERMINAL STRIP
ST CC F CC
RX CC
bipolar reference
Example programming for bipolar reference
Group
Parameter
New Value
UTILITY PARAMETERS
Blind Function Selection
1
UTILITY PARAMETERS
Frequency Setting Parameters Blind
1
FREQUENCY SETTING PARAMETERS
Frequency Priority Selection #1
3
FREQUENCY SETTING PARAMETERS
RX Terminal Standard or Adjustable
1
FREQUENCY SETTING PARAMETERS
RX Reference Setting Point #1
-100 (default)
FREQUENCY SETTING PARAMETERS
RX Point #1 Frequency
-60
FREQUENCY SETTING PARAMETERS
RX Reference Setting Point #2
100 (default)
FREQUENCY SETTING PARAMETERS
RX Point #2 Frequency
60