Toshiba B-SX5T-TS22-QM-R 用户手册

下载
页码 120
2.PRINTER SETUP 
ENGLISH VERSION EO1-33059 
2.13 Threshold Setting
 
E2-67 
2.13 Threshold Setting 
(Cont.) 
 
 
 
 
 
„  When using the Black Mark Sensor 
(1) While “<5>SENSOR ADJ.” is displayed, press the [PAUSE] key 
until the message appears.  
 
The displayed value is a real-time voltage being detected by the Black 
Mark Sensor. 
 
 
 
(2) 
Measure a voltage at a blank part of media and a black mark, 
respectively.  At this time, write down the midpoint between both 
voltages. (This value is used later for a threshold setting.) 
 (Example) 
Print area = 4.8V, Black mark = 2.4V  
 Midpoint = 3.6V 
 
 
 
 
 
 
 
 
 
 
(3) Press and hold the [RESTART] or [FEED] key for about 3 seconds 
aligning a blank part of print area with the Black Mark Sensor. 
 
(4) When storing a “media level” voltage is completed, an asterisk “*”is 
displayed on the right side of a voltage.  Press the [PAUSE] key. 
 
(5) A real-time voltage being detected by the Feed Gap Sensor is 
displayed.  
 
 
„  When using the Feed Gap Sensor 
(1)Measure a voltage at a blank part of label and a label gap, respectively.  
At this time, write down the midpoint of both voltages. (This value is 
used later for a threshold setting.) 
 (Example) 
Print area = 2.4V, Gap = 4.0V  
 Midpoint = 3.2V 
 
 
 
 
 
 
 
 
 
 
(2) Press and hold the [RESTART] or [FEED] key for about 3 seconds 
aligning a blank part of print area with the Feed Gap Sensor. 
 
(3) When storing a “media level” voltage is completed, an asterisk “*”is 
displayed on the right side of a voltage.  Press the [PAUSE] key.   
 
(4) The display changes as shown on the left.  
NOTES: 
1.  When measuring a voltage of a blank area, be careful not to align a
pre-print with the sensor by mistake. 
2.  Confirm that there is at least 0.7V difference between the two values.
If the difference in voltage is less than 0.7V, a print start position
cannot be detected.  In that case, please consider changing the media
type.  
3.  Make sure that the Top Cover is closed when measuring the voltages.
<5>SENSOR ADJ. 
[REFLECT] 3.5V 
<5>SENSOR ADJ. 
[REFLECT] 4.8V* 
<5>SENSOR ADJ. 
[TRANS.] 2.4V 
NOTES: 
1.  When measuring a voltage at a blank area, be careful not to align a
pre-print with the sensor by mistake. 
2.  Confirm that there is at least 0.7V difference between the two values.
If the difference in voltage is less than 0.7V, a print start position
cannot be detected.  In that case, please consider changing the media
type.  
3.  Make sure that the Top Cover is closed when measuring the voltages.
<5>SENSOR ADJ. 
[TRANS.] 2.4V 
<5>SENSOR ADJ. 
[TRANS.] 2.4V* 
<5>SENSOR ADJ. 
[PE]R0.1V  T4.8V
 
Voltage at a black mark 
Voltage at a print area 
Midpoint (Threshold voltage) 
Voltage at a label gap 
Voltage at a print area 
Midpoint (Threshold voltage) 
<5>SENSOR ADJ. 
[REFLECT] 3.5V