11.3 Extended parameters
• Input/output parameters 1
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
H
0100
Low-speed signal
output frequency
Hz
0.1/0.01
0.0-HJ
0.0
6.1.1
H
0101
Speed reach
setting frequency
Hz
0.1/0.01
0.0-HJ
0.0
6.1.3
H
0102
Speed reach
detection band
Hz
0.1/0.01
0.0-HJ
2.5
6.1.2
H
0108
Always active
function selection 1
-
-
0-71 (No function)
0
6.3.1
0: VIA - analog input
1: VIA - contact input (Sink)
H
0109
Analog/contact
input function
selection (VIA
terminal)
-
-
2: VIA - contact input (Source)
0
6.2.1
H
0110
Always-active
function selection 2
-
-
0-71 (ST)
1
6.3.1
H
0111
Input terminal
selection 1 (F)
-
-
0-71 (F)
2
H
0112
Input terminal
selection 2 (R)
-
-
0-71 (R)
3
H
0113
Input terminal
selection 3 (RES)
-
-
0-71 (RES)
10
H
0118
Input terminal
selection 8 (VIA)
-
-
0-71 (SS1)
6
6.3.2
H
0130
Output terminal
selection 1A
(RY-RC)
-
-
0-255 (LOW)
4
H
0132
Output terminal
selection 3 (FL)
-
-
0-255 (FL)
10
6.3.3
H
0137
Output terminal
selection 1B
(RY-RC)
-
-
0-255 (always ON)
255
6.3.4
0: H and H
H
0139
Output terminal
logic selection
(RY-RC)
-
-
1: H or  H
0
H
0167
Frequency
command
agreement
detection range
Hz
0.1/0.01
0.0-HJ
2.5
6.3.5
H
0170
Base frequency 2
Hz
0.1/0.01
25.0-200.0
50.0 (WP)
60.0 (WN)
H
0171
Base frequency
voltage 2
V
1/0.1
50-330 (200V class)
50-660 (400V class)
* 2
H
0172
Torque boost 2
%
0.1/0.1
0.0-30.0
* 1
6.4.1
H
0173
Motor electronic-
thermal protection
level 2
%
(A)
1/1
10-100
100
5.12
6.4.1
H
0185
Stall prevention
level 2
%
(A)
1/1
10-110,
111 (disabled)
110
6.4.1
6.17.2
*1 : Default values vary depending on the capacity.  
⇒ See the table of page K-14.
*2 : 
230 (WP/WN type), 400 (WP type), 460 (WN type)