11.17  Use and Adjustments of the Photocells
Photocell 1
The photocell does not operate at the fi rst machine starting ; when it is obscured by the next box the motorized 
plane of the infeed conveyor stops.  No adjustment is necessary.
Photocell 2
When is obscured by the box the motorized plane goes down and the side guides center the box.  No adjustment 
is necessary.
Photocell 3
It controls the closure of the side drives and and the descent of the rear fl ap folder.  The position can be changed 
according to box lengthy; move the photocell towards D for long boxes, towards S for short boxes.
Photocell 4
It stops the side drives and control the upper unit descent.  No adjustment is necessary.
Photocell 5
When the box is passed it controls the machine reset for a new working cycle.  No adjustment is necessary.
Photocell 6
When is obscured stops the machine and activates the ‘full line’ warning light on the control board. It's a tempo-
rary stop; he machine restarts just when the box is removed an so the photocell is rearmed. No adjustment is 
necessary.