Cabletron Systems 2E48-27R 用户手册

下载
页码 160
Chapter 2: Network Requirements
2-2
2E48-27R/2E49-27R User’s Guide
2.3
FOIRL FIBER OPTIC NETWORK
When connecting an FOIRL segment to any of the 2E49-27R ports 
(Interfaces 1 through 24), ensure that the network meets the Ethernet 
network requirements for FOIRL. Refer to the Cabletron Systems 
Cabling Guide for details.
2.4
100BASE-TX NETWORK
The 2E4X-27R, with an FE-100TX installed in ports 25 and 26, provides 
an RJ45 connection that supports UTP cabling, which has an impedance 
of 85 to 111 ohms. The device at the other end of the twisted pair segment 
must meet IEEE 802.3u 100BASE-TX Fast Ethernet network 
requirements for the devices to operate at 100 Mbps. Refer to the 
Cabletron Systems Cabling Guide for details.
2.5
100BASE-FX FIBER OPTIC NETWORK
Ports 25 and 26 of the 2E4X-27R support the Cabletron Systems 
FE-100FX and FE-100F3 fiber optic interface modules. The device at the 
other end of the fiber optic segment must meet the 100BASE-FX Fast 
Ethernet network requirements to operate at 100 Mbps. Refer to the 
Cabletron Systems Cabling Guide for details.
Multimode Mode Fiber Optic Cable Length
The maximum multimode fiber optic cable length of a 100BASE-FX 
segment is covered in the Cabletron Systems Cabling Guide
Single Mode Fiber Cable Lengths
The maximum single mode fiber optic length of a 100BASE-FX segment 
may be no more than 5 km between Data Terminal Equipment (DTE to 
DTE) in half duplex mode or 20 km (DTE to DTE) in full duplex mode.
NOTE
The 2E4X-27R with an FE-100TX installed is capable of 
operating at either 10 or 100 Mbps. The FE-100TX can 
automatically sense the speed of the other device and adjust 
its speed accordingly.