Raritan Computer 4.7 用户手册

下载
页码 257
Chapter 3: Rackmount and Installation 
 
34
 
 
a.  Connect a CIM to a server—see 
Specifications
 (on page 185
for specific instructions on connecting different CIM types to a 
server. 
b.  Plug one end of a Cat5 UTP cable into the RJ45 port on a CIM. 
c.  Plug the other end of cable into the RJ45 1-IN port on the back 
of HubPac. 
d.  Turn ON the server. 
e.  Repeat the above steps to connect the remaining servers, 
connecting the Cat5 UTP cable to the HubPac at the RJ45 2-IN, 
3-IN, 4-IN, 5-IN, 6-IN, 7-IN, and 8-IN port for each consecutive 
server (2 through 8) added. 
3.  Connect the HubPac to each Paragon switch by repeating all of the 
following steps for each 5-port cluster on the HubPac: 
Note: There are 8 five-port clusters on the HubPac. For each cluster 
the number in front of the RJ45 IN port represents the cluster 
number. For example, cluster 1’s first RJ45 port is 1 IN, cluster 2’s is 
2 IN, and so on. In the instructions below, “X” represents the cluster 
number (1 through 8). 
a.  Plug one end of a Cat5 UTP cable into the RJ45 X-1 port on the 
back of the HubPac. 
b.  Plug the other end of the cable into channel port # N on the back 
of one of the desired Paragon switches. 
c.  Plug one end of a Cat5 UTP cable into the RJ45 X-2 port on the 
back of the HubPac. 
d.  Plug the other end of the cable into channel port # N on the back 
of the second desired Paragon switch. 
e.  Plug one end of a Cat5 UTP cable into the RJ45 X-3 port on the 
back of the HubPac. 
f. 
Plug the other end of the cable into channel port # N on the back 
of the third desired Paragon switch. 
g.  Plug one end of a Cat5 UTP cable into the RJ45 X-4 port on the 
back of the HubPac. 
h.  Plug the other end of the cable into channel port # N on the back 
of the fourth desired Paragon switch. 
4.  Connect the power cord to the back of the HubPac. Turn ON the 
HubPac. 
5.  Turn ON each of the Paragon switches.